← Blowers & other equipment · series 4203

Stihl 4203 · Section L · 11 of 12 · 43 parts

Pressure pump

Fits SR 320, SR 400.

Parts diagrams →

Historical fitment & changes (3) — includes parts and conditions not shown on this drawing.

Position —

Go to table row → Where else is this used →
110111213141516171819191919191919192202122232425262728344041424356789
Tap a numbered callout to view that part. Use +/− or pinch to zoom. Scroll to browse.

Parts (43)

PosPart numberDescriptionQty
1 4203 162 3100 Coupling element option 1
2 4202 701 0500 Pump housing, top Fitment / change note → option 1
3 9640 003 0950 Oil seal 10x18x6 Fitment / change note → option 1
4 4203 700 2800 Shaft option 1
5 9503 003 5090 Grooved ball bearing 6000-2RS option 1
6 9455 621 0850 Circlip 10x1 option 1
7 9099 021 1760 Self-tapping screw 2.9x9.5 option 2
8 9307 021 0080 Washer 3.2 option 2
9 4202 704 0600 Impeller option 1
10 9210 319 0900 Hexagon nut M6 option 1
11 4202 708 8900 Sealing ring option 1
12 4203 701 0510 Pump housing, base option 1
13 9210 260 0600 Hexagon nut M4 option 2
14 9041 216 0650 Pan head screw M4x10 option 2
15 9104 003 0711 Self-tapping screw P4x20 option 4
16 4202 708 9502 Hose 10x2x830 mm option 1
17 4202 701 2400 Restrictor option 1
18 not sold separately Hose 330 mm / 13'' option 1
19 9771 021 1400 Hose clip 14-9 option 8
20 4203 700 0903 Container cap Fitment / change note → option 1
21 4203 709 2002 Sealing ring option 1
22 4112 141 2301 Twist lock option 1
23 4203 700 8801 Strainer option 1
24 4203 700 6312 Nozzle Ø 0.8 mm option 1
24 4203 700 6313 Nozzle Ø 1 mm Fitment / change note → option 1
24 4203 700 6314 Nozzle Ø 0.65 mm option 1
24 4203 700 6315 Nozzle Ø 1.6 mm Fitment / change note → option 1
24 4203 700 6316 Nozzle Ø 2 mm Fitment / change note → option 1
25 not sold separately Sealing ring optionnot available as a separate item 1
26 not sold separately Hose 400 mm / 15 13/16'' option 1
27 0000 706 4100 Cap option 1
28 4202 708 9101 Bow option 2
40 4203 700 6305 Nozzle Ø 1 mm, orange Fitment / change note → option 1
40 4203 700 6308 Nozzle Ø 1.6 mm, orange Fitment / change note → option 1
40 4203 700 6309 Nozzle Ø 2 mm, orange Fitment / change note → option 1
41 4202 708 6400 Spacer option 1
42 9645 945 0870 O-ring 10x2 option 1
43 4202 708 6301 Metering jet 1 option 1
43 4202 708 6302 Metering jet 2 option 1
43 4202 708 6303 Metering jet 3 option 1
Not numbered on the diagram — assemblies, kits and options
— 4203 007 1029 Pressure pump mounting kit (ULV) option 1
— 4203 700 0600 Pressure pump Fitment / change note → option 1
— 4202 708 9502 Hose 10x2x830 mm option 1

Parts are not interchangeable across engine series — check yours before ordering.

Historical fitment & changes

Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.

Historical fitment · SR 320 / SR 400

SR 320 / 400 only: container caps, pump-kit cap and larger strainer

Two cap replacements differ from retained old strainer supply; container and kit numbers stay unchanged.

  • This section explicitly applies to SR 320 AND SR 400 ONLY. Container 4203 700 0800 includes filler cap 4203 700 0900 → 4203 700 0902, which includes sealing ring 4203 709 2000. The container and ring numbers are unchanged.
  • The original scan recovers corrupted extracted row 4 as PRESSURE PUMP MOUNTING KIT 4203 007 1016, unchanged in both columns. It includes cap 4203 700 0901 → 4203 700 0903, which also includes sealing ring 4203 709 2000. Only the modified kit is factory-supplied; BOTH original cap versions are no longer available from factory.
  • Strainer 4203 700 8802 → 4203 700 8810 has increased capacity to simplify refilling; no volume or throughput is given. Figure 352TI002 KN labels LEFT original and RIGHT new. The original strainer REMAINS AVAILABLE FOR OLDER MACHINES, unlike the original caps.
  • Current SR catalog uses sealing ring 4203 709 2002 and ULV pump kit 4203 007 1029. Those edition/configuration differences are not silently substituted for TI ring 2000 or kit 1016; no supersession chain or universal kit equivalence is established.
  • Historical TI 14/1996 evidence, not current stock or a verified physical interchange claim. Introduction is in progress; no numeric serial boundary is given. Shared IPL sheets do not extend this note to BR 320 L or later models. No hardware operation was performed.

Source: TI 14/1996, p. 2 — SR 320 / 400 only: container caps, pump-kit cap and larger strainer.

Part numbers (9)
  • 4203 700 0800 — Container, unchanged numberTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 0900 — Original standard capTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 0902 — New standard capTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 709 2000 — Sealing ring, TI unchanged numberTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 007 1016 — Pressure pump mounting kit, modified version onlyTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 0901 — Original pump-kit capTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 0903 — New pump-kit capTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 8802 — Original strainer, still supplied for older machinesTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4203 700 8810 — New larger-capacity strainerTI14/1996 listed configuration · Only the note’s stated models and configuration

Service note · SR 320 / SR 400

SR 320 / 400 pressure pump: new seal, groove-free housing and repair lubrication

9638 003 0940 → 9640 003 0950; pack between bearing and seal with specified gear lubricant.

  • Pressure pump 4203 700 0600 retains its number and includes the seal and top housing. Oil seal 9638 003 0940 is replaced by 9640 003 0950. Top pump housing 4202 701 0500 retains its number but will have NO GROOVE in future. Only the modified pump and housing are factory-supplied; original seal is supplied only until existing factory stocks are exhausted.
  • IN THE EVENT OF REPAIR, pack the space BETWEEN THE BALL BEARING AND OIL SEAL with gear lubricant 0781 120 1109. No quantity, substitute lubricant, interval or seal-installation dimension is stated. This is not a direction to fill the entire pump.
  • The printed seal remark appears as “2)1”; the defined remarks are 1 and 2, with remark 2 specifying original-seal stock exhaustion. The extra trailing mark is retained as a source typographic ambiguity, not a third instruction.
  • The pressure pump is bound only to the retained SR 320 / SR 400 pressure-pump assembly, consistent with the SR-only container/pump-kit section. No pump fitment is claimed for BR blowers merely because they appear in the overall header. The footer reference to TI21/1994 is last-information bibliography, not a delegated missing procedure.
  • Historical TI 14/1996 evidence, not current stock or a verified physical interchange claim. Introduction is in progress; no numeric serial boundary is given. Shared IPL sheets do not extend this note to BR 320 L or later models. No hardware operation was performed.

Source: TI 14/1996, p. 4 — SR 320 / 400 pressure pump: new seal, groove-free housing and repair lubrication.

Part numbers (5)
  • 4203 700 0600 — Pressure pump, modified version onlyTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 9638 003 0940 — Original oil seal, supply until stocks exhaustedTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 9640 003 0950 — New oil sealTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 4202 701 0500 — Top housing, new version without grooveTI14/1996 listed configuration · Only the note’s stated models and configuration
  • 0781 120 1109 — Gear lubricant for space between bearing and sealTI14/1996 listed configuration · Only the note’s stated models and configuration

Conditional replacement · SR 320 / SR 400

SR 320 / SR 400: constant-volume kit and three nozzle sizes

Constant volume pump kit 4203 007 1026 replaces 1016; the new 1.0, 1.6 and 2.0 mm nozzles each include ring 4203 709 2001.

  • Section 3 ties the constant volume pump kit change to the standard-nozzle modification. Item 9 replaces 4203 007 1016 with 4203 007 1026 and expressly includes items 10 to 12. The TI does not enumerate a complete pump, hoses or mounting hardware as new kit contents; do not infer them from the kit name.
  • Item 10, diameter 1.0 mm: 4203 700 6305 becomes 4203 700 6313. Item 11, diameter 1.6 mm: 4203 700 6308 becomes 4203 700 6315. Item 12, diameter 2.0 mm: 4203 700 6309 becomes 4203 700 6316. Each new nozzle includes item 13, sealing ring 4203 709 2001. The Previous ring entry is a dash. The same ring number at ULV item 6 and constant-volume item 13 does not make the two nozzle-size groups interchangeable.
  • Remark 2: the original kit 1016 is supplied only until existing stocks are exhausted. Remark 3: all three original individual nozzles remain available as spares. No flow specification, size-selection procedure or full retrofit instruction is supplied.
  • The exact SR 320 / SR 400 pressure-pump sheet L lists the three modified nozzles at position 24 and the three original nozzles at position 40. Its pressure-pump mounting kit is 4203 007 1029, not TI kit 4203 007 1026; no supersession or identity between these kits is established. The position 25 sealing-ring row has no order number: it is not silently rewritten as 4203 709 2001. Source IPL rows and quantities remain unchanged.
  • Historical TI13/1999 applies to SR 320 and SR 400 sprayers, series 4203. Modification introduction is in progress; no serial boundary or exact introduction date is printed. All other parts remain as before. Factory availability remarks describe 1999 supply, not current stock. No later SR model, BR blower, complete retrofit procedure or physical interchange test is established.

Source: TI 13/1999, p. 1 · TI 13/1999, p. 2 — Complete USA pages: three modification sections and entire summary, all 13 numbered items plus complete ULV nozzle, inclusions and three availability remarks.

Part numbers (9)
  • 4203 007 1016 — Original constant volume pump kit; item 9Previous; stocks-exhausted supply limit, remark 2 · SR 320 / SR 400; original constant-volume kit
  • 4203 007 1026 — New constant volume pump kit; item 9Replaces 1016; includes items 10 to 12 · SR 320 / SR 400; modified constant-volume kit
  • 4203 700 6305 — Original nozzle diameter 1.0 mm; item 10Previous; remains available as spare, remark 3 · SR 320 / SR 400; original constant-volume nozzle
  • 4203 700 6313 — New nozzle diameter 1.0 mm; item 10Replacement includes sealing ring item 13 · SR 320 / SR 400; modified constant-volume nozzle
  • 4203 700 6308 — Original nozzle diameter 1.6 mm; item 11Previous; remains available as spare, remark 3 · SR 320 / SR 400; original constant-volume nozzle
  • 4203 700 6315 — New nozzle diameter 1.6 mm; item 11Replacement includes sealing ring item 13 · SR 320 / SR 400; modified constant-volume nozzle
  • 4203 700 6309 — Original nozzle diameter 2.0 mm; item 12Previous; remains available as spare, remark 3 · SR 320 / SR 400; original constant-volume nozzle
  • 4203 700 6316 — New nozzle diameter 2.0 mm; item 12Replacement includes sealing ring item 13 · SR 320 / SR 400; modified constant-volume nozzle
  • 4203 709 2001 — Sealing ring; item 13New entry; included with each modified constant-volume nozzle · SR 320 / SR 400; new constant-volume nozzles 6313 / 6315 / 6316

Wrong number or missing part for the SR 320, SR 400? Report a correction →