← P 835, P 840

Stihl 4702 · Section M · 12 of 14 · 29 parts

Pump housing P 840

Fits P 840.

Parts diagrams →

Historical fitment & changes (5) — includes parts and conditions not shown on this drawing.

Position —

Go to table row → Where else is this used →
110111213141516171819220212223242425262727273456789
Tap a numbered callout to view that part. Use +/− or pinch to zoom. Scroll to browse.

Parts (29)

PosPart numberDescriptionQty
1 4702 704 1200 Carrier 1
2 4702 700 4010 Pump housing 1
3 9121 347 1260 Stud M6x12 3
4 4702 007 1005 Set of gaskets 1
5 4702 704 3405 Rotor 1
6 4702 708 3105 Union nut 1
7 4702 700 4850 Inlet flange 2" 1
8 9645 945 8550 O-ring 75.87x2.62 1
9 4702 700 4853 Inlet flange 2" IPT-NPT 1
10 4702 700 4804 Flange 2" 1
11 9291 021 0140 Washer 6.4 3
12 9241 226 0900 Cap nut M6 3
13 4702 708 7505 Insert int. 1
14 4702 700 4700 Foot valve int. 1
15 4702 709 0410 Gasket 1
16 4702 706 4801 Flange 2" 1
17 9022 341 1010 Spline screw IS-M5x18 4
18 0000 359 1210 Sealing ring 1
19 0000 350 0515 Filler cap 1
20 4702 791 1702 Handlebar 1
21 0000 958 0608 Washer 1
22 9022 341 1300 Spline screw IS-M6x20 1
23 9220 260 0901 Hexagon nut M6 4
24 4702 708 8910 Gasket 2" 2
25 4702 708 8900 Gasket 2" 1
26 4702 708 3905 Hose connector 2" int. 2
27 4702 708 8608 Nut 2" 2
Not numbered on the diagram — assemblies, kits and options
— 4702 700 4852 Inlet flange 2" 1
— 4702 007 1051 Set of gaskets 1

Parts are not interchangeable across engine series — check yours before ordering.

Historical fitment & changes

Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.

Service note · P 835 / P 840

P 835 / P 840: centrifugal pump construction and dry-running limit

Bronze impeller and rubber/ceramic face seal require water; 08 S engine ancestry does not establish complete interchange.

  • Type 4702 pumps are intended primarily for irrigation and drainage on farms, in gardens and on building sites. Photo shows complete pump arrangement; it is not a dimensional drawing. Power unit uses the compact two-stroke 08 S engine attachment, also related to unnamed BT/TS applications, with protection against accidental hot-engine contact. This does not establish whole-machine or unnamed-model parts interchange.
  • Centrifugal pump housing comprises TWO corrosion-resistant aluminium-alloy diecast parts, bonded AND screwed together; intake and delivery ports are screwed on. Intake ends at the open blade side of the BRONZE-alloy impeller, with a vulcanized elastic ring protecting blade ends against abrasion from impurities. Axial face seal between impeller and housing uses RUBBER and CERAMIC sealing elements. No housing adhesive specification or seal-installation procedure is supplied on this page.
  • NEVER run the pumps DRY: the axial face seal will be damaged. P 835 self-priming does not mean dry-running capability; P 840 requires its foot valve and prefill. The conditions are model-specific and detailed in the separately linked priming notes.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 1 · TI 20/1994, p. 2 — P 835 / P 840: centrifugal pump construction and dry-running limit.

No additional parts-table entry added.

Service note · P 840

P 840: foot valve and complete pump-and-hose prefill are mandatory

Maximum flow 30 m³/h and head 35 m are not simultaneous; performance table uses a 2-inch connection.

  • P 840 must ALWAYS operate with a FOOT VALVE at the END OF THE SUCTION HOSE. Fill BOTH pump and suction hose with water BEFORE starting. Water must OVERFLOW through the pump-housing opening to ensure sufficient water in the suction hose. It is not described as self-priming like P 835. Never run dry: axial face seal damage results.
  • Maximum suction lift 7 m; maximum delivery height 35 m; maximum delivery volume 30 m³/h; maximum pressure 3.5 bar. Maxima are not simultaneous operating points. Numeric performance table is for 2-inch connection at suction lift 1.5 m and engine speed 6700 rpm.
  • Printed delivery-height [m] → volume [m³/h] pairs: 6→29.0; 9→27.0; 12→25.5; 15→23.5; 18→21.5; 21→19.0; 24→16.0; 27→12.0.
  • Page graph draws a straight P 840 line from 35 m at zero flow to zero head at 30 m³/h, whose intermediate values differ from the numeric table (table 27 m→12.0 m³/h). Preserve both representations without reconciling them silently or treating graphical interpolation as a measured curve. No physical performance has been verified.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 1 · TI 20/1994, p. 2 · TI 20/1994, p. 4 — P 840: foot valve and complete pump-and-hose prefill are mandatory.

No additional parts-table entry added.

Service note · P 835 / P 840

P 835 / P 840: tightening torque and adhesive depend on the exact joint

Twenty-five table rows retain component/thread mapping; four marked joints require Loctite 243.

  • Torque wrench is ESSENTIAL to achieve joint strength. Values below are Nm and apply to the printed component AND fastener, not a general thread-size rule. “Spline screw” wording follows the source; no unprinted part numbers inferred.
  • Spline screw M4×15, set of contacts: 1.0 Nm; M4×12, fanwheel: 7.0 Nm; IS-M4×16, armature plate: 3.3 Nm; IS-M4×25, carburetor flange: 3.3 Nm; nut VM5, filter port: 4.5 Nm.
  • Spline screw IS-M5×18, fan housing: 5.0 Nm; SAME thread/length, guard to fan housing: 2.8 Nm; IS-M5×25, guard to crankcase: 4.0 Nm; IS-M5×28, crankcase: 6.8 Nm; IS-M6×20, handle: 4.3 Nm WITH ADHESIVE; IS-M6×25, tank housing to crankcase housing: 7.0 Nm.
  • Spline screw M6×90, muffler to cylinder: 8.5 Nm; nut M6, muffler to housing: 8.5 Nm; spline screw IS-M6×20, cylinder: 9.5 Nm; IS-M5×18, shroud/crankcase housing: 2.0 Nm WITH ADHESIVE; nut M10×1, flywheel: 27.5 Nm; M14×1.25 spark plug: 25.0 Nm.
  • Spline screw B4.8×13, rubber buffer: 1.5 Nm; nut M6, inside of housing to engine: 8.5 Nm; nut M10×1 lks. (LEFT-HAND thread), rotor to crankshaft: 24.5 Nm WITH ADHESIVE; spline screw M4×19, ignition armature: 3.3 Nm; M4×10, air baffle to crankcase: 2.3 Nm WITH ADHESIVE.
  • Nut M6, intake port: 6.5 Nm; spline screw IS-M5×18, delivery port: 5.3 Nm; IS-M6×25, tank housing to pump housing: 7.0 Nm. Do not confuse intake and delivery fasteners or the two separate tank-housing joints.
  • Remark 1 requires adhesive 0786 111 1101 (LOCTITE 243) ONLY on four marked rows: handle, shroud/crankcase housing, rotor-to-crankshaft LEFT-HAND nut and air baffle to crankcase. Original scan aligns 2.0 Nm with shroud/crankcase and 27.5 Nm with flywheel; flattened text order must not swap them. Remark says “screw”, but its marker also explicitly applies to the rotor nut.
  • Source says adhesive-secured fasteners are easier to release after heating adhesive with a hot-air blower (hair dryer), with CAUTION on polymer components. No temperature, dwell time or permission to heat a fueled assembly is supplied. Housing-bond adhesive is not identified as this thread adhesive.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 5 — P 835 / P 840: tightening torque and adhesive depend on the exact joint.

Part numbers (1)
  • 0786 111 1101 — LOCTITE 243 adhesivefour marked fastener joints only · P 835 / P 840: tightening torque and adhesive depend on the exact joint

Service note · P 835 / P 840

P 835 / P 840: model weights, common dimensions and service accessories

Original total weights differ; carburetor and gasket kits have separate numbers.

  • Printed TOTAL weight: P 835 8.4 kg; P 840 7.9 kg. Source does not state a wet/dry weighing condition; do not invent one. Dimensions H×W×D are 380×350×300 mm, common table entry, not a mounting-hole template.
  • Accessories: combination wrench 1107 890 3400; screwdriver T27×120×70, number 0812 370 1145. Special service accessories: carburetor parts kit 4702 007 1060; set of gaskets 4702 007 1050. Kit contents, individual components and variant conversion are not specified; no such claims are inferred.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 5 — P 835 / P 840: model weights, common dimensions and service accessories.

Part numbers (4)
  • 1107 890 3400 — Combination wrenchaccessory · P 835 / P 840: model weights, common dimensions and service accessories
  • 0812 370 1145 — T27×120×70 screwdriveraccessory · P 835 / P 840: model weights, common dimensions and service accessories
  • 4702 007 1060 — Carburetor parts kitservice accessory; contents unspecified · P 835 / P 840: model weights, common dimensions and service accessories
  • 4702 007 1050 — Set of gasketsservice accessory; contents unspecified · P 835 / P 840: model weights, common dimensions and service accessories

Service note · P 835 / P 840

P 835 / P 840: historical workshop times and restricted trial run

Times assume trained personnel and a fully equipped shop; trial run is only with water or without the pump.

  • Same special tools as for 08 S chain saw may be used to repair the ENGINE UNIT of these pumps. This is not proof that every 08 S tool repairs the pump housing, nor whole-machine interchange; no special-tool numbers are printed.
  • Historical repair times in MINUTES for trained personnel and fully equipped customer repair shop: starter with pawls 15; shroud/air filter/carburetor/muffler 35; ignition module/switchgear/ignition armature 40; pump housing with impeller 20; cylinder and piston 60; crankcase and crankshaft 155; crankshaft bearings and rotary shaft seals 145; crankcase pressure test 30; trial run 5; tank 15; handle/stop switch/throttle control 5. These are quoted workshop allowances, not DIY completion promises or measurements.
  • Trial-run footnote: ONLY WITH WATER OR WITHOUT PUMP. Do not interpret a five-minute trial allowance as permission to run an assembled pump dry. Source requires applicable national safety rules and User Manual instructions when starting during repair/maintenance. No live test has been performed or authorized by this reference note.
  • Table is intended for insertion into page 15 of the STIHL repair-times table, by cutting/pasting or transcription. That document and User Manual are referenced, not accepted here as reviewed. Original publication footer is March 30, 1994.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 6 — P 835 / P 840: historical workshop times and restricted trial run.

No additional parts-table entry added.

Wrong number or missing part for the P 840? Report a correction →