← P 835, P 840

Stihl 4702 · Section N · 13 of 14 · 24 parts

Pump housing P 835

Fits P 835.

Parts diagrams →

Historical fitment & changes (5) — includes parts and conditions not shown on this drawing.

Position —

Go to table row → Where else is this used →
110111213141516171819220202121223456789
Tap a numbered callout to view that part. Use +/− or pinch to zoom. Scroll to browse.

Parts (24)

PosPart numberDescriptionQty
1 4702 704 1200 Carrier 1
2 4702 007 1005 Set of gaskets 1
3 4702 705 3000 Rotor 1
4 4702 708 3101 Union nut 1
5 9022 341 1080 Spline screw IS-M5x35 8
6 9210 260 0700 Hexagon nut M5 8
7 4702 709 0403 Gasket 1
8 4702 791 1702 Handlebar 1
9 0000 958 0608 Washer 1
10 9022 341 1300 Spline screw IS-M6x20 1
11 4702 701 0503 Pump housing, inner 1
12 4702 700 4003 Pump housing, outer 1
13 9645 945 8023 O-ring 42x3 1
14 4702 700 2700 Flap 1
15 4702 706 4800 Flange 1 1/4" 2
16 9022 341 0960 Spline screw IS-M5x12 → replaced by 9022 341 0980 TI 3/2006 6
17 4702 708 3902 Hose connector 1 1/4" 2
18 4702 708 3901 Hose connector 1 1/4" 2
19 4702 708 8600 Union nut 2
20 0000 350 0515 Filler cap 2
21 0000 359 1210 Sealing ring 2
22 9220 260 0901 Hexagon nut M6 4
Not numbered on the diagram — assemblies, kits and options
— 4702 007 1006 Rotor kit 1
— 4702 007 1051 Set of gaskets 1

Parts are not interchangeable across engine series — check yours before ordering.

Historical fitment & changes

Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.

Service note · P 835 / P 840

P 835 / P 840: centrifugal pump construction and dry-running limit

Bronze impeller and rubber/ceramic face seal require water; 08 S engine ancestry does not establish complete interchange.

  • Type 4702 pumps are intended primarily for irrigation and drainage on farms, in gardens and on building sites. Photo shows complete pump arrangement; it is not a dimensional drawing. Power unit uses the compact two-stroke 08 S engine attachment, also related to unnamed BT/TS applications, with protection against accidental hot-engine contact. This does not establish whole-machine or unnamed-model parts interchange.
  • Centrifugal pump housing comprises TWO corrosion-resistant aluminium-alloy diecast parts, bonded AND screwed together; intake and delivery ports are screwed on. Intake ends at the open blade side of the BRONZE-alloy impeller, with a vulcanized elastic ring protecting blade ends against abrasion from impurities. Axial face seal between impeller and housing uses RUBBER and CERAMIC sealing elements. No housing adhesive specification or seal-installation procedure is supplied on this page.
  • NEVER run the pumps DRY: the axial face seal will be damaged. P 835 self-priming does not mean dry-running capability; P 840 requires its foot valve and prefill. The conditions are model-specific and detailed in the separately linked priming notes.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 1 · TI 20/1994, p. 2 — P 835 / P 840: centrifugal pump construction and dry-running limit.

No additional parts-table entry added.

Service note · P 835

P 835: self-priming still requires water in the pump housing

Self-priming lift is 5.5 m; 7 m requires a foot valve. Delivery values depend on head and stated test conditions.

  • P 835 self-primes up to 5.5 m suction lift ONLY with sufficient water already in the pump housing. Maximum suction lift is 7 m WITH FOOT VALVE. Never run dry because the axial face seal will be damaged. Do not read “self-priming” as permission to start with an empty housing.
  • Maximum delivery height 45 m, maximum delivery volume 12 m³/h, maximum pressure 4.5 bar. These maxima are NOT simultaneous operating points. Performance table uses 1¼-inch connection, suction lift 1.5 m and engine speed 6700 rpm.
  • Printed delivery-height [m] → volume [m³/h] pairs: 6→11.5; 10→11.3; 14→10.5; 18→9.0; 22→8.0; 26→6.7; 30→6.0; 34→5.4. Do not transfer the P 840 values or different-connection assumptions.
  • The same page draws a straight P 835 line from 45 m at zero flow to zero head at 12 m³/h. Its plotted straight-line intermediate values do NOT reproduce the numeric table (for example, table 34 m→5.4 m³/h). Retain graph and table as differing printed representations; use the explicit table without interpolating the graph into invented measured data. No physical pump performance has been verified.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 1 · TI 20/1994, p. 2 · TI 20/1994, p. 4 — P 835: self-priming still requires water in the pump housing.

No additional parts-table entry added.

Service note · P 835 / P 840

P 835 / P 840: tightening torque and adhesive depend on the exact joint

Twenty-five table rows retain component/thread mapping; four marked joints require Loctite 243.

  • Torque wrench is ESSENTIAL to achieve joint strength. Values below are Nm and apply to the printed component AND fastener, not a general thread-size rule. “Spline screw” wording follows the source; no unprinted part numbers inferred.
  • Spline screw M4×15, set of contacts: 1.0 Nm; M4×12, fanwheel: 7.0 Nm; IS-M4×16, armature plate: 3.3 Nm; IS-M4×25, carburetor flange: 3.3 Nm; nut VM5, filter port: 4.5 Nm.
  • Spline screw IS-M5×18, fan housing: 5.0 Nm; SAME thread/length, guard to fan housing: 2.8 Nm; IS-M5×25, guard to crankcase: 4.0 Nm; IS-M5×28, crankcase: 6.8 Nm; IS-M6×20, handle: 4.3 Nm WITH ADHESIVE; IS-M6×25, tank housing to crankcase housing: 7.0 Nm.
  • Spline screw M6×90, muffler to cylinder: 8.5 Nm; nut M6, muffler to housing: 8.5 Nm; spline screw IS-M6×20, cylinder: 9.5 Nm; IS-M5×18, shroud/crankcase housing: 2.0 Nm WITH ADHESIVE; nut M10×1, flywheel: 27.5 Nm; M14×1.25 spark plug: 25.0 Nm.
  • Spline screw B4.8×13, rubber buffer: 1.5 Nm; nut M6, inside of housing to engine: 8.5 Nm; nut M10×1 lks. (LEFT-HAND thread), rotor to crankshaft: 24.5 Nm WITH ADHESIVE; spline screw M4×19, ignition armature: 3.3 Nm; M4×10, air baffle to crankcase: 2.3 Nm WITH ADHESIVE.
  • Nut M6, intake port: 6.5 Nm; spline screw IS-M5×18, delivery port: 5.3 Nm; IS-M6×25, tank housing to pump housing: 7.0 Nm. Do not confuse intake and delivery fasteners or the two separate tank-housing joints.
  • Remark 1 requires adhesive 0786 111 1101 (LOCTITE 243) ONLY on four marked rows: handle, shroud/crankcase housing, rotor-to-crankshaft LEFT-HAND nut and air baffle to crankcase. Original scan aligns 2.0 Nm with shroud/crankcase and 27.5 Nm with flywheel; flattened text order must not swap them. Remark says “screw”, but its marker also explicitly applies to the rotor nut.
  • Source says adhesive-secured fasteners are easier to release after heating adhesive with a hot-air blower (hair dryer), with CAUTION on polymer components. No temperature, dwell time or permission to heat a fueled assembly is supplied. Housing-bond adhesive is not identified as this thread adhesive.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 5 — P 835 / P 840: tightening torque and adhesive depend on the exact joint.

Part numbers (1)
  • 0786 111 1101 — LOCTITE 243 adhesivefour marked fastener joints only · P 835 / P 840: tightening torque and adhesive depend on the exact joint

Service note · P 835 / P 840

P 835 / P 840: model weights, common dimensions and service accessories

Original total weights differ; carburetor and gasket kits have separate numbers.

  • Printed TOTAL weight: P 835 8.4 kg; P 840 7.9 kg. Source does not state a wet/dry weighing condition; do not invent one. Dimensions H×W×D are 380×350×300 mm, common table entry, not a mounting-hole template.
  • Accessories: combination wrench 1107 890 3400; screwdriver T27×120×70, number 0812 370 1145. Special service accessories: carburetor parts kit 4702 007 1060; set of gaskets 4702 007 1050. Kit contents, individual components and variant conversion are not specified; no such claims are inferred.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 5 — P 835 / P 840: model weights, common dimensions and service accessories.

Part numbers (4)
  • 1107 890 3400 — Combination wrenchaccessory · P 835 / P 840: model weights, common dimensions and service accessories
  • 0812 370 1145 — T27×120×70 screwdriveraccessory · P 835 / P 840: model weights, common dimensions and service accessories
  • 4702 007 1060 — Carburetor parts kitservice accessory; contents unspecified · P 835 / P 840: model weights, common dimensions and service accessories
  • 4702 007 1050 — Set of gasketsservice accessory; contents unspecified · P 835 / P 840: model weights, common dimensions and service accessories

Service note · P 835 / P 840

P 835 / P 840: historical workshop times and restricted trial run

Times assume trained personnel and a fully equipped shop; trial run is only with water or without the pump.

  • Same special tools as for 08 S chain saw may be used to repair the ENGINE UNIT of these pumps. This is not proof that every 08 S tool repairs the pump housing, nor whole-machine interchange; no special-tool numbers are printed.
  • Historical repair times in MINUTES for trained personnel and fully equipped customer repair shop: starter with pawls 15; shroud/air filter/carburetor/muffler 35; ignition module/switchgear/ignition armature 40; pump housing with impeller 20; cylinder and piston 60; crankcase and crankshaft 155; crankshaft bearings and rotary shaft seals 145; crankcase pressure test 30; trial run 5; tank 15; handle/stop switch/throttle control 5. These are quoted workshop allowances, not DIY completion promises or measurements.
  • Trial-run footnote: ONLY WITH WATER OR WITHOUT PUMP. Do not interpret a five-minute trial allowance as permission to run an assembled pump dry. Source requires applicable national safety rules and User Manual instructions when starting during repair/maintenance. No live test has been performed or authorized by this reference note.
  • Table is intended for insertion into page 15 of the STIHL repair-times table, by cutting/pasting or transcription. That document and User Manual are referenced, not accepted here as reviewed. Original publication footer is March 30, 1994.
  • Historical TI 20/1994 guidance for explicitly named models only; no successor or unlisted variant applicability inferred. Factory supply statements are historical, not current stock claims. MOQ columns are order quantities, not fitting quantities. No physical interchange test was performed.

Source: TI 20/1994, p. 6 — P 835 / P 840: historical workshop times and restricted trial run.

No additional parts-table entry added.