← SE 100, SE 200, SE 201, SE 202

Stihl 4901 · Section A · 1 of 11 · 37 parts

Machine cover, Motor housing

Fits SE 100, SE 200, SE 201, SE 202.

Parts diagrams →

Historical fitment & changes (3) — includes parts and conditions not shown on this drawing.

Position —

Go to table row → Where else is this used →
110111213141516171819220212222232425262728293303132333445506789
Tap a numbered callout to view that part. Use +/− or pinch to zoom. Scroll to browse.

Parts (37)

PosPart numberDescriptionQty
1 4709 700 2100 Machine cover 1
2 4709 706 3200 Soundproofing liner no longer available from factory 1
3 4709 706 3205 Soundproofing liner 1
4 4709 706 3500 Push nut 4
5 4727 608 9000 Rubber ring 1
6 4709 706 3215 Soundproofing liner 1
7 4709 700 6600 Air diverter 1
8 not sold separately Soundproofing liner not available as a separate item 1
9 4709 706 1800 Spring catch 4
10 4709 703 4100 Handle no longer available from factory 1
11 9063 319 8110 Countersunk screw M6x90 2
12 4714 703 3800 Sleeve 1
13 9210 260 0755 Hexagon nut R1/2" 1
14 4714 706 1800 Clip no longer available from factory 1
15 4709 600 0800 Motor housing 1
16 4709 706 3225 Soundproofing liner 1
17 4709 706 3230 Soundproofing liner 1
18 4709 706 3235 Soundproofing liner 1
19 4709 706 3500 Push nut 10
20 4709 706 3240 Soundproofing liner 1
21 4713 431 2900 Terminal block no longer available from factory 1
22 9104 003 8650 Self-tapping screw P3.5x18 3
23 4709 600 2900 Module 1
24 9104 003 9939 Self-tapping screw P3.5x10 2
25 4709 605 1201 Interference suppressor capacitor Fitment / change note → 1
25 4709 605 1206 Interference suppressor capacitor Fitment / change note → 1
26 9189 021 2860 Wood screw 3.5x50 1
27 4703 431 2500 Cable clamp 1
28 9104 003 8778 Self-tapping screw P5x20 3
29 4901 440 2000 Connecting cable 1
30 4901 440 2030 Connecting cable 1
31 4901 440 2010 Connecting cable 1
32 4703 440 2000 Connecting cable GB 110 V 1
33 4901 440 2020 Connecting cable 1
34 4709 440 2000 Connecting cable 1
50 4709 605 1200 Interference suppressor capacitor Fitment / change note → 1
50 4709 605 1205 Interference suppressor capacitor Fitment / change note → 1

Parts are not interchangeable across engine series — check yours before ordering.

Historical fitment & changes

Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.

Service note · SE 100 / SE 200 / SE 201 / SE 202

SE 100 / 200 / 201 / 202: motor conversion preserves locking-pin alignment

Transfer the upper ring, align opposite pins and reconnect mains at filter markings A and B.

  • Expert-electrician procedure: remove vacuum top; remove TWO handle Phillips screws and handle; invert top, remove THREE Phillips screws shown, return top upright. Remove THREE clamping-plate Phillips screws and plate. Remove old motor with earth connection and upper bearing ring; remove TWO hex-socket bolts(1) and upper ring.
  • Engage locking pins(2) OPPOSITE one another in new motor. Align upper-ring holes with pins and fit ring. Place motor in support plate; turn clamping plate until pins align with its recesses, then insert/tighten three Phillips screws. Diagram distinguishes old bolted ring from pin alignment; no tightening torque supplied.
  • If present, REMOVE OLD thermal safeguard with main cable from clamping plate; new motor already has built-in safeguard. Hook main cable to suppression-filter markings A and B. Replace cover/handle in reverse order. DO NOT EARTH NEW CLASS II MOTOR. This is not permission to omit built-in protection or the outlet earth. Test electrical/technical safety to IEC335 after conversion.
  • Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
  • Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.

Source: TI 29/1994, p. 1 · TI 29/1994, p. 2 — SE 100 / 200 / 201 / 202: motor conversion preserves locking-pin alignment.

No additional parts-table entry added.

Service note · SE 100 / SE 200 / SE 201 / SE 202

SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate

General and S/N/SF/GB 120 V rows change numbers; both original parts remain supplied.

  • General suppression capacitor 4709 605 1200→4709 605 1201; separate row labelled S/N/SF/GB120V is 4709 605 1205→4709 605 1206. Original parts STILL AVAILABLE(remark2). Introduction IN PROGRESS, no serial.
  • No capacitance, voltage equivalence, universal substitution or120V replacement motor is established by this capacitor row. Expert-electrician restriction and post-conversion IEC335 test remain applicable.
  • Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
  • Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.

Source: TI 29/1994, p. 3 — SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate.

Part numbers (4)
  • 4709 605 1200 — Suppression capacitorold still available · SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate
  • 4709 605 1201 — Suppression capacitornew · SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate
  • 4709 605 1205 — S/N/SF/GB120V suppression capacitorold still available · SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate
  • 4709 605 1206 — S/N/SF/GB120V suppression capacitornew · SE 100 / 200 / 201 / 202: suppression-capacitor variants remain separate

Service note · SE 100 / SE 200 / SE 202

SE 100 / 200 / 202: automatic-switch kit removes half-power mode

230–240 V kit 4901 007 1000 changes position I to maximum speed and position II to accessory-triggered operation.

  • Kit 4901 007 1000 is230–240V ONLY; no120V or SE201 applicability. PositionI: vacuum runs MAXIMUM RPM because power-halving device must be removed. PositionII: built-in outlet ON, vacuum turns on with an accessory at that outlet (example grinding-machine extraction). Source literally says device plugged in; no current threshold, delay, load rating or guarantee that an idle plugged-in tool triggers it is supplied.
  • Expert electrician: dismantle handle/cover as preceding section; disconnect all cables EXCEPT CONNECTING CABLE; REMOVE output-halving unit(3). Slide switch board(4) into holding frame and SNAP frame onto AIR-INTAKE SCREEN. Wire to page7, then replace cover/handle in reverse order. After conversion electrical/technical safety MUST be tested to IEC335. No installation torque, PCB part number or revised manual acceptance inferred.
  • Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
  • Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.

Source: TI 29/1994, p. 6 · TI 29/1994, p. 7 — SE 100 / 200 / 202: automatic-switch kit removes half-power mode.

Part numbers (1)
  • 4901 007 1000 — Automatic switching retrofit230–240Vnew kit;SE100/200/202 only · SE 100 / 200 / 202: automatic-switch kit removes half-power mode

Wrong number or missing part for the SE 100, SE 200, SE 201, SE 202? Report a correction →