Stihl 4901 · Section B · 2 of 11 · 34 parts
Panel, Switch
Fits SE 100, SE 200, SE 201, SE 202.
Historical fitment & changes (5) — includes parts and conditions not shown on this drawing.
Parts (34)
| Pos | Part number | Description | Qty |
|---|---|---|---|
| 1 | 4709 602 7600 | Module no longer available from factory | 1 |
| 2 | 4709 602 7605 | Module | 1 |
| 3 | 4709 602 7610 | Module | 1 |
| 4 | 4709 602 7616 | Module | 1 |
| 4 | 4709 602 7609 | Module | 1 |
| 5 | 4709 602 7620 | Module | 1 |
| 6 | 4714 602 7620 | Panel | 1 |
| 7 | 4714 602 7600 | Panel | 1 |
| 8 | 4714 602 7605 | Panel | 1 |
| 9 | 4714 602 7610 | Panel | 1 |
| 10 | 4709 430 0500 | Switch | 1 |
| 11 | 4709 430 0506 | Switch | 1 |
| 12 | 4713 430 0500 | Switch | 1 |
| 13 | 4709 430 0510 | Switch | 1 |
| 14 | 4713 430 0500 | Switch | 1 |
| 15 | 4714 430 0510 | Switch | 1 |
| 16 | 4709 430 1300 | Socket | 1 |
| 17 | 4709 430 1305 | Socket | 1 |
| 18 | 4709 430 1310 | Socket | 1 |
| 19 | 4709 430 1315 | Socket | 1 |
| 20 | 4709 430 1320 | Socket | 1 |
| 21 | 9045 421 0740 | Socket head screw M4x25 | 2 |
| 22 | 9309 021 0100 | Washer 4.3 | 2 |
| 23 | 9210 260 0600 | Hexagon nut M4 | 4 |
| 24 | 9048 319 0680 | Pan head screw M4x16 | 4 |
| 25 | 9330 630 0100 | Shake-proof washer 4.3 | 4 |
| 26 | 9104 003 8778 | Self-tapping screw P5x20 | 4 |
| 27 | 9062 118 0680 | Countersunk screw M4x16 | 4 |
| 28 | 4714 437 0400 | Pilot lamp | 1 |
| 28 | 4714 437 0405 | Pilot lamp | 1 |
| 29 | 4714 701 6000 | Hose 3x1.5x150 mm no longer available from factory | 1 |
| 30 | 9104 003 9939 | Self-tapping screw P3.5x10 | 2 |
| 40 | 4709 602 7615 | Module | 1 |
| 41 | 4713 430 0500 | Switch | 1 |
Parts are not interchangeable across engine series — check yours before ordering.
Historical fitment & changes
Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.
Service note · SE 100 / SE 200 / SE 202
SE 100 / 200 / 202: switch terminal names differ by version
A1 maps to 2, A2 to 1, A3 to 3; B4 maps to 5, B5 to 4, B6 to 6.
- Model1 terminal functions: A2=N input; A1=N output inII; A3=N output inI; B5=L1 input; B4=L1 output inII; B6=L1 output inI. Model2:1=N input;2=N output inII;3=N output inI;4=L1 input;5=L1 output inII;6=L1 output inI.
- Functional mapping A1↔2,A2↔1,A3↔3,B4↔5,B5↔4,B6↔6. Diagrams viewed as printed: Model1 top A1/B4,middle A2/B5,bottom A3/B6; Model2 top2/5,middle1/4,bottom3/6. Do not equate suffix numbers or invent a mating-side connector orientation. No switch part number given. SE201 excluded from this subsection. Qualified-electrician work only.
- Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
- Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.
Source: TI 29/1994, p. 3 — SE 100 / 200 / 202: switch terminal names differ by version.
No additional parts-table entry added.
Service note · SE 100 / SE 200 / SE 202
SE 100 / 200 / 202: standard circuit retains power reduction and socket earth
Page 4 uses lettered switch terminals and a reduction module A1, not the later retrofit controller A1.
- Observed diagram legend: A1=engine-power reduction, C1=suppression capacitor, M1=classII motor, Q1=switch, X1=connecting cord, X2=terminal block, X3=outlet. Component A1 and Q1 terminal A1 are DIFFERENT identifiers.
- Visible nets: X2 L1→Q1 B5 and one X3 pole; X2 N→Q1 A2. Q1 A1 is bridged to A3, C1 neutral side and one M1 lead. A3 also goes to other X3 pole. B4 connects C1 line side, other M1 lead and one side of reduction module; B6 connects the other reduction-module side. Diagram therefore bypasses reduction inII and routes through it inI. This is source tracing, not a tested live wiring procedure.
- Protective earth runs X1→X2→X3 only; M1 has no drawn earth connection. Do not remove X3 earth when converting motor to classII. No wire colors, connector pin-view convention, test voltages or module values provided. Expert-electrician work and IEC335 test apply; exact original diagram is controlling evidence.
- Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
- Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.
Source: TI 29/1994, p. 3 · TI 29/1994, p. 4 — SE 100 / 200 / 202: standard circuit retains power reduction and socket earth.
No additional parts-table entry added.
Service note · SE 201
SE 201: separate circuit includes negative-pressure indicator B1/H1
SE 201 uses a two-position switch and is not included in the automatic-switch retrofit.
- Legend: B1/H1=negative-pressure control (pressure switch and lamp shown), C1=suppression capacitor, M1=classII motor, Q1=switch, X1=connecting cord, X2=terminal block, X3=outlet. Q1 positions0/1, not the other models’ I/0/II.
- Visible nets: X2 L1→Q1 B5; X2 N→Q1 A2. Switched B4/A1 feed M1, C1 and both X3 current-carrying poles in parallel. B1/H1 branch spans B4/A1 through pressure switch and indicator lamp in series, NOT in series with motor. X1/X2 protective earth continues to X3, not M1.
- No pressure threshold, conductor color or test value supplied. SE201 is NOT named for section2 automatic kit; shared replacement motors do not extend kit applicability. Expert-electrician restriction and IEC335 post-conversion test remain.
- Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
- Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.
Source: TI 29/1994, p. 5 — SE 201: separate circuit includes negative-pressure indicator B1/H1.
No additional parts-table entry added.
Service note · SE 100 / SE 200 / SE 202
SE 100 / 200 / 202: automatic-switch kit removes half-power mode
230–240 V kit 4901 007 1000 changes position I to maximum speed and position II to accessory-triggered operation.
- Kit 4901 007 1000 is230–240V ONLY; no120V or SE201 applicability. PositionI: vacuum runs MAXIMUM RPM because power-halving device must be removed. PositionII: built-in outlet ON, vacuum turns on with an accessory at that outlet (example grinding-machine extraction). Source literally says device plugged in; no current threshold, delay, load rating or guarantee that an idle plugged-in tool triggers it is supplied.
- Expert electrician: dismantle handle/cover as preceding section; disconnect all cables EXCEPT CONNECTING CABLE; REMOVE output-halving unit(3). Slide switch board(4) into holding frame and SNAP frame onto AIR-INTAKE SCREEN. Wire to page7, then replace cover/handle in reverse order. After conversion electrical/technical safety MUST be tested to IEC335. No installation torque, PCB part number or revised manual acceptance inferred.
- Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
- Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.
Source: TI 29/1994, p. 6 · TI 29/1994, p. 7 — SE 100 / 200 / 202: automatic-switch kit removes half-power mode.
Part numbers (1)
- 4901 007 1000 — Automatic switching retrofit230–240Vnew kit;SE100/200/202 only · SE 100 / 200 / 202: automatic-switch kit removes half-power mode
Service note · SE 100 / SE 200 / SE 202
SE 100 / 200 / 202: automatic-kit circuit uses numbered switch and controller terminals
Page 7 retains F1 and the capacitor earth branch; do not substitute page 4’s reduction-module wiring.
- Page7 drawing uses numbered Q1 terminals and controller A1 with terminals1–7. A1 here is AUTOMATIC-SWITCH BOARD from section2, NOT page4 power-reduction component. X1=cord,X2=terminal block,X3=outlet,C1=capacitor,M1=motor by preceding legends; F1 is a drawn series protective-switch symbol without its own printed legend/value.
- Observed nets: X2 L1→Q1 4; X2 N→Q1 1. Q1 5→one X3 pole; other X3 pole→controller A1 terminal1. Q1 2→A1 terminal2; Q1 4→A1 terminal3; Q1 6→A1 terminal4. Q1 6 and3 feed C1 input pair. C1 output goes to M1, with F1 in one motor lead. A1 terminals5/6/7 have NO EXTERNAL WIRES DRAWN; do not invent jumpers or roles.
- Protective-earth line from X2 branches to X3 AND C1-side branch; unlike pages4/5 the diagram retains external F1 and capacitor-earth branch. It does NOT explicitly draw a motor-frame earth connection. Motor variant for this diagram is not explicitly qualified. Do not erase drawn branches or use it to override the explicit ban on earthing the new classII motor. Preserve this variant/context limitation; source tracing is not an electrically verified installation.
- Qualified-electrician installation and post-conversion IEC335 safety test required. Footer29August1994. Original schematic retained as exact evidence; no wire colors, connector view, F1 threshold or internal controller design inferred.
- Historical TI 29/1994 guidance only. No successor or unlisted model applicability inferred. Factory supply statements are historical, not current availability. No physical interchange test was performed.
- Exact vacuum models are grouped under catalogue series4901, despite TI type4709/4714. Sheet C is SE100 motor/filter; sheet D is SE200/201/202; shared sheets A/B cover housing and switches. Shared sheet labels do not broaden this note’s explicit model scope.
Source: TI 29/1994, p. 6 · TI 29/1994, p. 7 — SE 100 / 200 / 202: automatic-kit circuit uses numbered switch and controller terminals.
Part numbers (1)
- 4901 007 1000 — Automatic switch retrofitcircuit context only · SE 100 / 200 / 202: automatic-kit circuit uses numbered switch and controller terminals
Wrong number or missing part for the SE 100, SE 200, SE 201, SE 202? Report a correction →