| Pos | Part number | Description | Qty |
|---|---|---|---|
| 1 | 4726 701 1200 | Valve block | 1 |
| 2 | 9645 945 7494 | O-ring 8.76x1.78 | 1 |
| 3 | 4719 700 6200 | Valve | 6 |
| 4 | 9645 951 3341 | O-ring 12x2 | 6 |
| 5 | 9045 319 1380 | Socket head screw M6x35 | 4 |
| 6 | 4719 510 0150 | Housing no longer available from factory | 1 |
| 7 | 9132 216 1235 | Grub screw M6x8 Fitment / change note → | 1 |
| 8 | 4719 510 0305 | Control piston Fitment / change note → no longer available from factory | 1 |
| 9 | not sold separately | Valve seat insert not available as a separate item | 1 |
| 10 | not sold separately | Ball not available as a separate item | 1 |
| 11 | not sold separately | Valve body not available as a separate item | 1 |
| 12 | not sold separately | Bow not available as a separate item | 1 |
| 13 | 4719 431 6000 | Retainer | 1 |
| 14 | 4719 430 0500 | Switch Fitment / change note → | 1 |
| 15 | 9645 945 7564 | O-ring 15x2 | 4 |
| 16 | 9045 319 1070 | Socket head screw M5x30 | 4 |
| 17 | 4719 512 0500 | Pressure gauge | 1 |
| 18 | 4719 510 0205 | Non-return valve Fitment / change note → | 1 |
| 19 | 9645 945 7450 | O-ring 4.47x1.78 | 1 |
| 20 | 4719 518 0200 | Spring | 1 |
| 21 | 4719 510 1600 | Connector Fitment / change note → no longer available from factory | 1 |
| 22 | 9645 945 7641 | O-ring 20.24x2.62 Fitment / change note → | 1 |
| 23 | 4719 518 0300 | Banjo bolt no longer available from factory | 1 |
| 24 | 4719 709 0300 | High-pressure cup | 3 |
| 25 | 4719 518 0600 | Washer Ø 16x11x1 mm | 1 |
| Not numbered on the diagram — assemblies, kits and options | |||
| — | 4719 007 1050 | Set of gaskets option | 1 |
Parts are not interchangeable across engine series — check yours before ordering.
Historical fitment & changes
Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.
Service note · RE 102 KM / RE 104 KM / RE 106 KM
RE KM: valve-block and non-return-valve changes have different scopes
The valve-block replacement is listed only for RE 102/104; the non-return valve includes its O-ring.
- Valve block (11) is explicitly RE 102/104 K 4719 701 1200 → RE 102/104 KM 4719 701 1210, new MOQ 1. NO RE 106 valve-block replacement is specified. Do not extend that pair to RE 106 merely because this note links the shared model sheet.
- Non-return valve (12) 4719 510 0200 → 4719 510 0205 includes item 13, O-ring 4x2, 9645 945 7445. Original valve carries remark 1; its new MOQ cell is BLANK in the source, not a known fitted quantity. O-ring MOQ 1. Sealing ring (14) 4719 519 0200 is newly listed, MOQ 1. Valve and rings have no narrower model qualifier in this table; this does not widen the explicitly restricted valve-block row.
- Exploded view distinguishes small O-ring 13 at non-return valve 12 from the larger separate sealing ring 14. No pressure adjustment or unprinted seal material specified.
- Historical TI 36/1994 guidance only. No serial cutoff, retrofit kit or blanket K-to-KM interchange is specified. Remark 1 means the original part remains available for OLDER MACHINES, not that old and new configurations are freely interchangeable. Supply statements are historical, not current stock. No physical interchange test was performed. No hardware operation was performed.
Source: TI 36/1994, p. 2 · TI 36/1994, p. 3 · TI 36/1994, p. 4 — RE KM: valve-block and non-return-valve changes have different scopes.
Part numbers (6)
- 4719 701 1200 — RE 102/104 ONLY valve block; item 11; originalold; retained for older machines · RE KM: valve-block and non-return-valve changes have different scopes
- 4719 701 1210 — RE 102/104 ONLY valve block; item 11; newnew · RE KM: valve-block and non-return-valve changes have different scopes
- 4719 510 0200 — Non-return valve including item 13; item 12; originalold; retained for older machines · RE KM: valve-block and non-return-valve changes have different scopes
- 4719 510 0205 — Non-return valve including item 13; item 12; newnew · RE KM: valve-block and non-return-valve changes have different scopes
- 9645 945 7445 — O-ring 4x2; item 13included seal · RE KM: valve-block and non-return-valve changes have different scopes
- 4719 519 0200 — Sealing ring; item 14new seal · RE KM: valve-block and non-return-valve changes have different scopes
Service note · RE 102 KM / RE 104 KM / RE 106 KM
RE 102 / 104 / 106 KM: automatic-cutout control block and service parts
Inserted U-retained control piston; five included pieces not supplied individually.
- Automatic cutout stops the motor with the spray gun closed, reducing energy use and noise and simplifying operation. The pressure delay valve connects pump delivery to intake during starting to reduce starting torque/current; no current, pressure or speed threshold is specified.
- The safety control block incorporates automatic cutout and pressure delay. Its control piston is INSERTED and retained by a U-fastener rather than screwed into the housing. The pressure control knob is deleted; operating pressure is controlled on the new spray lance.
- Control piston 4719 510 0305 incorporates items5–9: valve seat, ball, valve body, U-bar and retainer. ALL FIVE are not available individually under remark2; no individual TI numbers are supplied. Grub screw M6x8 9132 216 1235 is already in the product line (remark1). Switch is 4719 430 0500.
- TI casing numbers are 4719 511 0105 for RE102KM/104KM and 4719 511 0115 for RE106KM. Current 4719/C IPL instead lists housing4719 510 0150 and a separately numbered retainer4719 431 6000. These are unresolved edition/supply differences, not silently substituted TI numbers or an inferred supersession.
- Historical TI15/1996 evidence only. From January 1996; page7 separately prints “Modification to be introduced from machine no. 31 168 816”. Neither statement is a universal model-identification range or proof of retrofit compatibility. RE 102 K is only for some markets; no extension to RE 104 K / RE 106 K or later models. No hardware operation was performed.
Source: TI 15/1996, p. 1 · TI 15/1996, p. 6 · TI 15/1996, p. 7 — RE 102 / 104 / 106 KM: automatic-cutout control block and service parts.
Part numbers (5)
- 4719 511 0105 — CasingTI15/1996 listed configuration · RE 102 KM / RE 104 KM
- 4719 511 0115 — CasingTI15/1996 listed configuration · RE 106 KM
- 9132 216 1235 — Grub screw M6x8; existing product-line partTI15/1996 listed configuration · Only the stated models and configuration
- 4719 510 0305 — Control piston including items5–9TI15/1996 listed configuration · Only the stated models and configuration
- 4719 430 0500 — SwitchTI15/1996 listed configuration · Only the stated models and configuration
Service note · RE 102 KM / RE 104 KM / RE 106 KM
RE 102 / 104 / 106 KM: pressure-delay and automatic-cutout states
Nine diagrams explain start, open-gun operation, trapped outlet pressure, stop and restart.
- Figures607TI001–009 describe the new system, not a diagnostic test. A=intake, B=delivery, C=trapped outlet-pressure region, HD=high-pressure outlet; V1=bypass valve, V2=non-return valve, K1=control piston, F1=spring, H1=lever. The hydraulic figures call the microswitch S1; the electrical diagram on page9 calls it B2 and uses S1 for the main switch. These diagram-local labels must not be conflated.
- Idle/motor off: piston2 presses ball1 onto the BOTTOM seat. Starting with unit switch on and gun open: flow lifts ball against piston2/spring3 and partly returns to A, limiting immediate pump load. Sufficient flow at an unspecified speed moves the ball to the TOP seat and closes the intake connection. K1 initially remains in the F1-held idle position with V2 closed; increasing B pressure opens V2.
- Open gun: V1 CLOSED, V2 fully OPEN, with operating pressure in B, C and spray attachment. Closing gun raises B/C above working pressure; C moves K1 against F1 and pushes ball1 off its top seat. B pressure falls; C>B closes V2. Almost full cutout pressure remains in C, holding V2 closed and bypass open.
- Bypass/gun closed: K1 via H1 actuates the hydraulic-diagram S1 to switch motor OFF; control-piston spring presses ball to bottom seat. Reopening gun discharges C, F1 returns K1, H1 releases switch and motor restarts; the starting sequence repeats. The illustration does not mean the outlet is depressurized merely because the motor is stopped.
- Historical TI15/1996 evidence only. From January 1996; page7 separately prints “Modification to be introduced from machine no. 31 168 816”. Neither statement is a universal model-identification range or proof of retrofit compatibility. RE 102 K is only for some markets; no extension to RE 104 K / RE 106 K or later models. No hardware operation was performed.
Source: TI 15/1996, p. 1 · TI 15/1996, p. 2 · TI 15/1996, p. 3 · TI 15/1996, p. 4 · TI 15/1996, p. 7 · TI 15/1996, p. 9 — RE 102 / 104 / 106 KM: pressure-delay and automatic-cutout states.
No additional parts-table entry added.
Service note · RE 102 KM / RE 104 KM
RE 102 / 104 KM: revised outlet connector; RE 106 KM excluded
Connector includes 20.24x2.62 O-ring; RE102K prose/table scope differs.
- Section3 replaces the non-return-valve banjo bolt with connector4719 510 1600 on RE102 K/KM and RE104KM. RE106KM high-pressure hose outlet is UNCHANGED. Table rows11–12 name only RE102KM/104KM, so its omission of RE102K is retained rather than treating the table as a K-model parts confirmation.
- Connector incorporates O-ring20.24x2.62 9645 945 7641. No universal banjo-bolt replacement or RE106KM conversion is inferred.
- Historical TI15/1996 evidence only. From January 1996; page7 separately prints “Modification to be introduced from machine no. 31 168 816”. Neither statement is a universal model-identification range or proof of retrofit compatibility. RE 102 K is only for some markets; no extension to RE 104 K / RE 106 K or later models. No hardware operation was performed.
Source: TI 15/1996, p. 1 · TI 15/1996, p. 6 · TI 15/1996, p. 7 — RE 102 / 104 KM: revised outlet connector; RE 106 KM excluded.
Part numbers (2)
- 4719 510 1600 — Outlet connector including O-ringTI15/1996 listed configuration · Only the stated models and configuration
- 9645 945 7641 — O-ring20.24x2.62TI15/1996 listed configuration · Only the stated models and configuration
Service note · RE 102 KM / RE 104 KM / RE 106 KM
RE 102 / 104 / 106 KM: material-specific torque and microswitch setting
Brass15 Nm / aluminium10 Nm; half-turn follows switch-off, with pressure-setting dependency.
- Valve-block/pump-casing screwed connection: BRASS valve block tightening torque INCREASED TO15 Nm; ALUMINIUM block remains10 Nm. No blanket15 Nm setting for all blocks or other fasteners, no previous brass value and no added lubrication condition are stated.
- If operated during repair/maintenance, follow country-of-use safety regulations and Owner’s Manual safety instructions. Section9.1 delegates pressure-control adjustment to the SERVICE INSTRUCTIONS; the rotary knob is no longer present. The required exact-model pressure-setting procedure/value and Owner’s Manual are not in the retained reviewed manual inventory/catalog. This is an explicit source dependency, not a complete stand-alone service procedure.
- Historical section9.2 sequence: unscrew travel-limiting screw1 completely; switch on; adjust pressure control using the missing service instruction; set maximum pressure on lance; run ABOUT10 seconds while opening/closing gun2 OR3 times. With motor ON and gun CLOSED, screw in travel stop until motor switches OFF, then a FURTHER HALF-TURN. Check at MINIMUM pressure and adjust if necessary; operate gun a few times, verifying motor ON with gun open and OFF with gun closed; repeat adjustment if necessary. No torque, pressure value, thread pitch or bypass of the preceding pressure adjustment is inferred.
- Historical TI15/1996 evidence only. From January 1996; page7 separately prints “Modification to be introduced from machine no. 31 168 816”. Neither statement is a universal model-identification range or proof of retrofit compatibility. RE 102 K is only for some markets; no extension to RE 104 K / RE 106 K or later models. No hardware operation was performed.
Source: TI 15/1996, p. 1 · TI 15/1996, p. 7 · TI 15/1996, p. 8 — RE 102 / 104 / 106 KM: material-specific torque and microswitch setting.
No additional parts-table entry added.
Service note · RE 102 KM / RE 104 KM / RE 106 KM
RE 102 / 104 / 106 KM: automatic-cutout wiring and diagram-local labels
Electrical B2 is the microswitch; hydraulic S1 must not be confused with electrical S1.
- Electrical diagram607TI018 labels B1=thermal protector, B2=microswitch, C1=capacitor, M1=motor, S1=main switch, X1=terminal strip. Circled1/2/3/4 wire colours are RED/BLACK/WHITE/CLEAR respectively. Hydraulic figures use S1 for the microswitch instead: labels are local to their diagram.
- X1 terminals are L1, N, 1 and2; C1 bridges1 and2. S1 contacts4–5 lie in the L1 branch, with B2 below; contacts1–2 lie in the N branch. Red circled1 is the switched L1/B2 motor feed, black circled2 the switched N branch through B1, white circled3 connects X1/1 to the red-side motor node, and clear circled4 connects X1/2 to the other motor winding. The lower winding ends join the black/B1-side common. PE connects separately to the indicated motor/enclosure earth, not to a numbered colour circuit.
- Circled wire identifiers are NOT X1 terminal numbers. No wire gauge, capacitor rating, motor winding resistance or live-test procedure is supplied. Use the original diagram for topology; no connection was made or verified. Footer TI36/1994 is last-information bibliography, not a substitute for the explicitly delegated service instructions.
- Historical TI15/1996 evidence only. From January 1996; page7 separately prints “Modification to be introduced from machine no. 31 168 816”. Neither statement is a universal model-identification range or proof of retrofit compatibility. RE 102 K is only for some markets; no extension to RE 104 K / RE 106 K or later models. No hardware operation was performed.
Source: TI 15/1996, p. 1 · TI 15/1996, p. 7 · TI 15/1996, p. 9 — RE 102 / 104 / 106 KM: automatic-cutout wiring and diagram-local labels.
No additional parts-table entry added.
Wrong number or missing part for the RE 102 KM, RE 104 KM, RE 106 KM? Report a correction →