← BE 55, BGE 60

Stihl 4804 · Section D · 4 of 5 · 20 parts

Housing BGE 60

Fits BGE 60.

Parts diagrams →

Historical fitment & changes (7) — includes parts and conditions not shown on this drawing.

Position —

Go to table row → Where else is this used →
110111213141516171823456789
Tap a numbered callout to view that part. Use +/− or pinch to zoom. Scroll to browse.

Parts (20)

PosPart numberDescriptionQty
1 4807 791 1105 Handle molding, left 1
2 4807 791 1100 Handle molding, right 1
3 4807 967 1802 Rating plate 100 V 1
4 4807 967 1801 Rating plate 120 V 1
5 4807 791 6600 Flap 1
6 4807 791 8200 Torsion spring 1
7 9074 478 4425 Pan head self-tapping screw IS-P6x19 8
8 4804 706 8000 Screen 1
9 4807 998 0800 Torsion spring 1
10 4807 700 1800 Blower tube 1
11 4807 708 6300 Nozzle 1
12 4227 700 7102 Hose clip 1
13 4227 701 5000 Screw 1
14 4807 703 5600 Screen 1
15 4227 708 0105 Adapter option 1
16 4227 700 7105 Hose clip option 3
17 4227 708 3405 Tube option 3
18 4227 708 6905 Manifold option 2
Not numbered on the diagram — assemblies, kits and options
— 4227 007 1005 Gutter cleaning kit option 1
— 0000 884 0307 Safety glasses not illustratedoption 1

Parts are not interchangeable across engine series — check yours before ordering.

Historical fitment & changes

Source-reviewed service notes supplement this IPL. These are not extra drawing positions or a complete revision history. Availability statements belong to the bulletin’s date.

Service note · BGE 60

BGE 60: housing, cord grip and household blower configuration

Single-phase electric blower with an integral handle and cord restraint; the vacuum attachment is optional equipment.

  • Page1 introduces BGE60 series4807 for household leaf, paper and debris blowing on flowerbeds, lawns and paths. Photograph shows the blower tube, integral handle and short connecting lead. No internal parts or dimensions are inferred from the photograph.
  • Page2 section1 specifies a single-phase AC drive motor in a high-impact plastic housing. The housing cord grip relieves strain on the plug; the handle is integral with the housing and carries an ON/OFF switch.
  • The vacuum attachment is a SPECIAL ACCESSORY, not included by this introduction. Residential-noise/directive marketing is historical context, not evidence of current legal compliance or permission to operate. No bayonet attachment or interlock design is supplied here.
  • Historical BGE 60, TI38/1998 series 4807, 120 V / 60 Hz specification only. Catalog grouping under 4804 does not equate the series or extend BE 55 procedures to BGE 60. No serial changeover, later-model compatibility or current availability inferred. No hardware operation was performed.

Source: TI 38/1998, p. 1 · TI 38/1998, p. 2 — Introduction and photograph; complete section1.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: airflow, noise, weight and dimensions

Keep blower/vacuum modes, the 50-foot noise distance and tube-excluded dimensions distinct.

  • Blower-mode sound pressure is63 dB(A) at50 ft to ANSI B175.2-1990. It is not sound power or an operator-ear measurement. The historical standard designation is retained, not replaced by a newer method.
  • Maximum air flow362 cfm; in VACUUM MODE at9,800 RPM315 cfm. Air velocity is printed203 ft/s–138 m.p.h. Do not merge the two flow values or treat the rounded speed pair as two operating settings.
  • Weight FULLY ASSEMBLED2.9 kg (6.4 lbs). Dimensions WITHOUT BLOWER TUBE: length375 mm (14.76 in), width210 mm (8.26 in), height330 mm (13.0 in). No unsupported vacuum-assembly weight or full tube-equipped length inferred.
  • Historical BGE 60, TI38/1998 series 4807, 120 V / 60 Hz specification only. Catalog grouping under 4804 does not equate the series or extend BE 55 procedures to BGE 60. No serial changeover, later-model compatibility or current availability inferred. No hardware operation was performed.

Source: TI 38/1998, p. 2 — Section2 complete noise table, airflow, weight and dimensions.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: motor-housing screw torque

IS-P 6 x 19 motor-housing screw: 3.0 Nm (2.2 lbf.ft).

  • Section4 contains one row: spline screw IS-P6 x19 for MOTOR HOUSING, torque2.2 lbf.ft /3.0 Nm. These are paired units for the same joint, not two settings.
  • This does not establish torque for fanwheel, electrical connectors, switch or other fasteners. No screw order number, tightening sequence, thread preparation or reuse limit is supplied.
  • Historical BGE 60, TI38/1998 series 4807, 120 V / 60 Hz specification only. Catalog grouping under 4804 does not equate the series or extend BE 55 procedures to BGE 60. No serial changeover, later-model compatibility or current availability inferred. No hardware operation was performed.

Source: TI 38/1998, p. 3 — Section4 entire torque table including unit headings.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: spline drivers and connector crimping tool

The three listed tools have specific screw/connector applications; no electrical test settings are given.

  • Section5 lists screwdriver bit for torque wrench I-5 x120 x6.3,0812 542 2104, for IS spline screws; T-handle screwdriver QI-5 x150,5910 890 2400, also for IS spline screws; crimping tool5910 890 8210 for cable connectors,lugs,etc.
  • The tool table supplies no terminal pinout, wire size, crimp die, insulation-test instrument or Hi-Pot voltage/duration/leakage limit. A listed hand driver is not itself a torque-limiting device. Tool names/numbers are procedural references, not motor replacement parts.
  • Historical BGE 60, TI38/1998 series 4807, 120 V / 60 Hz specification only. Catalog grouping under 4804 does not equate the series or extend BE 55 procedures to BGE 60. No serial changeover, later-model compatibility or current availability inferred. No hardware operation was performed.

Source: TI 38/1998, p. 3 — Section5 complete three-row table.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: repair times and motor-failure warranty exception

The starred 0.2-hour motor entry covers historical whole-machine warranty handling, not motor replacement labor.

  • Section7 assumes trained personnel in a properly equipped service workshop. Units are TENTHS OF AN HOUR;0.1h=6minutes. All repair times INCLUDE electrical leakage test (Hi-Pot test) time; this is not a test procedure or evidence a machine passed.
  • Complete table: code1 Power Cord0.4h;2 On/Off Switch0.4h;3 Replace Motor Housing0.5h;4 Drive Tube,Drive Shaft DASH;5 Blower Tube0.3h;6 Replace Gear Box/Arbor Assy.DASH;7 Replace Arbor Gears DASH;8 Replace Motor STARRED0.2h;20 Misc.Repairs0.5h. Dashes are not zero-time repairs, missing part recommendations or blower drive-shaft/gearbox fitment.
  • The asterisk says REPLACE COMPLETE MACHINE for WARRANTY failures of the BGE60 motor. The0.2h allowance is for completing the warranty claim and returning the machine to the STIHL Distributor. Do not present it as12minutes of motor-removal/installation labor, an owner obligation, current warranty entitlement or an instruction to contact a distributor.
  • No additivity or total repair duration is specified. This bulletin supplies no Hi-Pot settings, discharge procedure or detailed electrical repair method; those remain unestablished and no energized test was performed.
  • Historical BGE 60, TI38/1998 series 4807, 120 V / 60 Hz specification only. Catalog grouping under 4804 does not equate the series or extend BE 55 procedures to BGE 60. No serial changeover, later-model compatibility or current availability inferred. No hardware operation was performed.

Source: TI 38/1998, p. 4 — Section7 complete nine-row repair table, all preconditions, asterisk and Hi-Pot note.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: 2002 housing compatibility is one-way

New housing halves may serve earlier BGE 60 machines; that does not permit the new harness on an older machine.

  • Page 1 service note says BOTH housing halves were adapted to accept the modified harness. New housing halves CAN also be used for previous machine models. The separate prohibition on fitting the new harness to older machines remains in force; replacing housings is not an authorized conversion recipe.
  • Drawing 291TI002 KN compares LEFT-HAND housing halves; 291TI003 KN compares RIGHT-HAND halves. In EACH pair, LEFT is previous and RIGHT is new. The added/changed internal retaining geometry accommodates the capacitor/wire arrangement; no cut, drill, glue or hand-modification method is specified.
  • The reverse direction (old housings on a new machine) is not authorized. No new/previous housing order numbers, dimensional tolerances or required modification of an old shell are printed. Retained 2012 handle-molding numbers do not establish which 2002 revision is on an individual machine.
  • Historical BGE 60, series 4807, TI 22/2002 English/USA only; the numbered harness row is USA/CDN. No serial changeover, BE 55 applicability, 230 V conversion, current stock availability or energized repair/test procedure is established. No hardware operation was performed.

Source: TI 22/2002, p. 1 — Entire service note and both labeled housing-comparison diagrams.

No additional parts-table entry added.

Service note · BGE 60

BGE 60: 2002 capacitor and cable routing diagram

Use the new-version routing figure; this is not a pinout or electrical safety-test specification.

  • Page 2 Routing requires BOTH cable routing and capacitor position to match 291TI004 KN. The square-bodied capacitor is drawn in the upper-left internal pocket, below the switch region; the leads follow the depicted molded routes around the motor and to its terminals. These are orientation cues to the original figure, not an inferred wire-color map.
  • The entire drawing, including the housing edge, motor, terminals and supports, was reviewed. Do not substitute the earlier capacitor-free harness picture or BE 55 routing. No conductor colors, terminal numbering, capacitor discharge method, electrical test voltage/duration/leakage limit or complete circuit schematic is provided.
  • This is a later new-version BGE 60 harness instruction only, not a substitute for the owner-safety precautions and Hi-Pot procedure absent from the 1998 introduction. The footer identifies copyright 2002 and document 7745; no production serial or original 1998 electrical configuration can be inferred.
  • Historical BGE 60, series 4807, TI 22/2002 English/USA only; the numbered harness row is USA/CDN. No serial changeover, BE 55 applicability, 230 V conversion, current stock availability or energized repair/test procedure is established. No hardware operation was performed.

Source: TI 22/2002, p. 2 — Complete routing instruction and291TI004 KN figure; footer.

No additional parts-table entry added.

Wrong number or missing part for the BGE 60? Report a correction →